Netcomm NP2724M User Manual

Browse online or download User Manual for Network switches Netcomm NP2724M. NetComm NP2724M User's Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1

User GuideNP2724M User Guidewww.netcomm.com.auVLAN Managed Switch

Page 2 - Table of Contents

Web-Browser You can manage the switch through a web connection by connecting to the switch’s IP address using your web browser. NP2724M default I

Page 3 - 1. Introduction

Switch. This interface allows you to access the switch using the Web browser of your choice. 2.8.1. Logging on the switch To log on to the Switch:

Page 4 - 2. Installation

User Mode When the operator logs into the CLI, the User Mode is the initial mode. The User Mode contains a limited set of commands. The command pro

Page 5

This command is used to exit from the telnet Format logout Mode User Mode ping This command sends echo messages. Format ping <A.B.C.D> Mode

Page 6

This command is used to clear static arl table entries Format clear arl static mac <mac-addr> Mode Privileged Mode 4) clear config This comman

Page 7 - 2.6. Rack- Mount Placement

2) copy system_image This command is used to backup switch runtime image Format copy system_image tftp <A.B.C.D> <filename> Mode Privile

Page 8

This command display the queue-settings mapping Format show qos queue-settings Mode Privileged Mode 1. 3) show qos advanced This command display qos

Page 9 - Configuration

4) show interface This command is used to display summary statistics 4.1) show interface history This command is used to display port RX and TX Format

Page 10

Mode Privileged Mode 9) show network This command is used to configuration for inband connectivity Format show network Mode Privileged Mode 10) sho

Page 11 - 2.8.1. Logging on the switch

3) show snmp communities This command display all snmp communities Format show snmp communities Mode Privileged Mode 15) show sntp This command is u

Page 12 - 2.9.2. User Mode commands

Table of Contents 1. Introduction...2 1.1. Package Conten

Page 13

Format show switch admin-time Mode Privileged Mode 19.2) show switch age-time This command display the age time of L2 table Format show switch age-

Page 14

This command displays rmon event log. Format show rmon event log event index <1..65535> Mode Privileged Mode 22.6) show rmon history This co

Page 15

1.2) vlan add range This command enter a range of vlan ID Format vlan add range from < vlan-ID > to <vlan-ID> Mode Global Config 2) vlan

Page 16

Mode Global Config 5) vlan lag This command is used to configure lag to a special vlan 5.1) vlan lag vlan < vlan-id> exclude This command is us

Page 17

Mode Global Config 3) lldp adv-interval This command is used to specify advertised interval in seconds Format lldp adv-interval <5-32768> Mode

Page 18

2.2) log logging-target flash This command is used to specify flash log notify-level Format log logging-target flash {enable|disable} Mode Privilege

Page 19

2) monitor disable This command disables port mirroring. Format monitor disable Mode Global Config 3) monitor des Configure destination port. 3.1) m

Page 20

Mode Global Config 3) network protocol This command configure switch dhcp client. Format network protocol {dhcp|none} Mode Global Config 4) network

Page 21

This command configures ports auto-negotiation mode. Format port-all auto-negotiate {enable|disable} Mode Global Config 3) port-all flow-control Thi

Page 22

unicast. Format port-all storm-control broadcast-unknown <value> Mode Global Config 8.5) port-all storm-control all-cast This command configur

Page 23

1. Introduction Thank you for choosing the NetComm NP2724M 24 port 10/100 + 2 Gigabit VLAN Managed Switch. These switches are a cost-effective switch

Page 24

This command configures queue weight for weight round robin. Format qos wrr weight <1-15> queue <1-4> Mode Global Config 8) qos dscp-rem

Page 25

Mode Global Config 3) set igmp-proxy This command configures igmp proxy. Format set igmp-proxy {enable | disable} Mode Global Config 4) set static-

Page 26

5) snmp trapstation 5.1) snmp trapstation add Create a snmp trap station. 5.1.1) snmp trapstation add <ip-addr> community <community name>

Page 27

Format sntp server enable Mode Global Config 3.2) sntp server ipaddr This command sets sntp server IP address. Format sntp server ipaddr <IP-add

Page 28

This command configure the number of hops in a region. Format spanning-tree max-hops <1-40> Mode Global Config 6) spanning-tree port 6.1) spa

Page 29

This command creates a MST instance. Format spanning-tree mst vlan <MST ID> <vlan list> add Mode Global Config e.g. Switch(Config)# S

Page 30

3.1) rmon del event This command deletes rmon event entry. Format rmon del event index< 1..65535 > Mode Global Config 3.2) rmon del alarm Th

Page 31

This command clears a source mac address. Format Access-list name <WORD> clear mac SA Mode Global Config 3.6) access-list name <WORD>

Page 32

6.4) access-list name <WORD> set IP-mode packet-type This command specifies the packet type. Format access-list name <WORD> set IP-mode pa

Page 33

Set auto-authorized on ports Format 802.1x port-control {enable|disable} Mode Interface Config lacp 1) admin command Configure admin key of port

Page 34

2. Installation This chapter describes the function of the NP2724M switch components and shows how to install it on the desktop or shelf. Basic knowl

Page 35

Mode Interface Config 4.2) 8021 set Status of local-802.1 settings Format lldp tlvs-tx {enable | disable} option 8021 {pvid | vlanname | proto

Page 36

Mode Interface Config qos This command specifies port-based qos. Format qos port-based status {enable | disable} Mode Interface Config ra

Page 37

Mode Interface Config set igmp-router-port This command specifies igmp router port . Format set igmp-router-port {enable | disable} Mode Inte

Page 38

Format vlan participation exclude < vlan id> Mode Interface Config 1.2) vlan participation This command join a vlan with untagged/tagged mod

Page 39

Format poe detection type {0 | 1 | 2 | 3 | 4 | 5} Mode Interface Config 4)high-power This command configures power Energy Mode on a port on S

Page 40

3. Specifications 3.1. Cable specifications Straight-Through and Crossed-Over Cable Specifications Table Ethernet Type Cable Requirements Maximu

Page 41

Crossover Cables has a different pin arrangement at each end. Figure 4-1 shows the diagram of Straight-through Cables. Figure 4-2 shows the diagra

Page 42

3.2. Technical Specifications 3.2.1. Software Specification NP2724M 24 Port 10/100 + 2 Gigabit VLAN Managed Switch □Four groups (history, statisti

Page 43

co-operate with the RADIUS servers. □Supports broadcast, known-multicast, and unknown uni-cast storm control □Supports web-based interface for manage

Page 44

Power 100~120/200~240 VAC~1.0 A/0.5 A 50~60Hz Operating Temp. 0 ℃ ~ 40 ℃(32  ~ 104 ) Storage Temp. -40  ~ 70 (-40  ~ 158 ) Operating Humidity 20

Page 45 - 3. Specifications

connection. G1, G2 This is where you connect the Cat. 5e or better Ethernet cable for 10/100/1000 Mbps Ethernet connection miniGBIC This is where you

Page 46

4. Legal & Regulatory Information This manual is copyright. Apart from any fair dealing for the purposes of private study, research, criticism or

Page 47

1. You, or someone else, use the product, or attempts to use it, other than as specified by NetComm; 2. The fault or defect in your product is the

Page 48

Product WarrantyNetComm products have a standard 12 months warranty from date of purchase. However some products have an extended warranty option, via

Page 49 - 3.2.4. Standard Conformance

Figure 2.5.1 Network Configuration for NP2724M (NEED TO REPLACED BY the FRONT PANEL IMAGE of a NP2724 swtich) Read and perform the following pro

Page 50 - Customer Information

Keep enough ventilation space between the switch and the surrounding objects. Note: When choosing a location, keep in mind the environmental restri

Page 51 - Limitations of Warranty

other than direct connections to the branch circuit (e.g. use of power strips)." To mount the Switch in any standard-sized, 19-inch wide, 1U hig

Page 52 - Technical Support

Configuration This Chapter will describe the use of the NP2724M Management configuration program. 2.7. Preparing for configuration NP2724M offe

Comments to this Manuals

No comments